MAP 35÷50cm3
Application:
Options:
Advantages:
Алтернатива на
Rexroth: A4FM, A10FM;
Linde: HMF-02;
Poclain: M2,M3;
Sauer Danfoss: 90M,40M;
PWG: MF;
Bondioli&Pavesi: HPM7, M8, M4MF;
Technical data
Code |
Working volume cm3/rev [in3/rev] |
Max. speed RPM |
Max. Torgue** *Nm [lb-in] |
Output kW [HP] |
Max. Pressure bar [PSI] |
Max. Oil Flow l/min [GPM] |
|||||
| cont. | int* | cont. | int** | cont. | int** | cont. | int** | cont. | int* | ||
| MAP 35 | 36,16 [2.21] | 4000 | 4500 | 202 [1789] | 242 [2142] | 58 [78] | 84 [113] | 350[5080] | 420 [6100] | 145 [38.3] | 163 [43.1] |
| MAP 40 | 41,59 [2.54] | 4000 | 4500 | 232 [2053] | 278 [2640] | 67 [90] | 97 [130] | 350 [5080] | 420 [6100] | 167 [44.1] | 187 [49.4] |
| MAP 46 | 47,13 [2.88] | 4000 | 4500 | 263 [2328] | 315 [2788] | 76 [102] | 110 [148 ] | 350 [5080] | 420 [6100] | 189 [50] | 212 [56] |
| MAP 50 | 49.94 [3.05] | 4000 | 4200 | 278 [2460] | 326 [2885] | 76 [102] | 110 [148 ] | 350 [5080] | 410 [5950] | 180 [47.5] | 210 [55.5] |
|
* Intermitten speed (flow) is for pressure up to 150 [2200] bar [PSI] ** Intermitten load: the permissible values may occur for max. 10% of product lifetime. *** Theoretical torque General: |
|||||||||||
| Min Speed | RPM | 500 | |||||||||
| Max Pressure in Drain Line | bar [PSI] | 5 [70] | |||||||||
| Pressure fluid | Mineral based- HLP(DIN 51524) or HM(ISO 6743/4) | ||||||||||
| Temperature range. | °C [°F] |
-40+82 [-40+180] | |||||||||
| Optimal Viscosity range. | cSt | 12+68 [70+320] | |||||||||
| Filtration | ISO code 18/16/13 (Min. recommended fluid filtration of 10 micron) | ||||||||||